Standard Platinum Resistance Thermometer I. DescriptionThe Standard Platinum Resistance Thermometer is used for compensation in standard temperature range of 13.8033k—961.8°C, and used as a standard.
See the detailed thermometers in the table below:
Type |
Classification |
Suitable Temperature Zone |
Working Length (mm) |
Temperature |
WZPB-1 |
I |
0~419.527℃ |
470±10 |
Medium |
WZPB-1 |
I |
83.8058K~419.527℃ |
470±10 |
Full |
WZPB-2 |
II |
0~419.527℃ |
470±10 |
Medium |
WZPB-2 |
II |
83.8058K~419.527℃ |
470±10 |
Full |
WZPB-7 |
I |
0~660.323℃ |
510±10 |
Medium |
WZPB-7 |
I |
83.8058K~660.323℃ |
510±10 |
Full |
WZPB-8 |
II |
0~660.323℃ |
510±10 |
Medium |
WZPB-8 |
II |
83.8058K~660.323℃ |
510±10 |
Full |
Note: The Rtp of the above thermometers is 25±1.0Ω.The external diameter of quartz tubes is φ7±0.6mm.our factory also manufactures the platinum thermometer with the temperature zone of 83.8058K~660.323℃ as the working basic standard instrument.
Use Information
1. Before using, firstly, check the thermometer number to be consistent with the test certificate.
2. When using, according to the lug logo of the thermometer wire terminal, connect the wire correctly. The lug
① of the red wire is connected to the current positive terminal; the lug
②of the black wire, to the potential positive terminal; the lug
③of the yellow wire, to the current negative terminal; and the lug
④of the green wire, to the potential negative terminal.
The following is the outline of the thermometer:
3. The current should be 1MA according to the measuring of the temperature component of the thermometer.
4. For matching the electrical measurement device of the thermometer for measuring temperature, the low resistance potentiometer of grade 1 and the standard coil resistance of grade 0.1 or the measuring precise temperature bridge as well as the accessories should be used. The complete set of electrical measuring device should be guaranteed to have the sensitivity to distinguish the changing of one ten-thousandth Ohm.
5. During the process of using, preservation and transportation, try to avoid the severe mechanical vibration of the thermometer.
6. When using the first grade Standard Platinum Resistance Thermometer to test the temperature of the second grade Standard Platinum Resistance Thermometer, should follow the verification procedures approved by National Measurement Bureau.
7. The regular test of the thermometer should be done stringently according to the relevant verification procedures and regulations .