The LAB set is defined to cover requirements that are most often required in test laboratories or R&D department’s for type testing. One of the most important test to be carried out is the dielectric withstand test which can be destructive or non-destructive. The MI 3394 supports the execution of both. To execute the destructive withstanding test, the Burn Link Adapter (A 1560) must be used. The set includes also a set of professional HV test pistols for carrying out AC + DC HV tests safely. The rest of the available tests can be carried out via different test terminals. All the tested data can be stored on an 8GB micro SD card.
MI 3394 LB CE MultiTesterXA |
---|
Extra Features | Workspaces | Industrial Mode | |
Portable appliance Mode | |||
Laboratory Use Mode | |||
Project Structure | |||
Visual Inspection Mode | |||
Functional Inspection Mode | |||
AUTOSEQUENCE ® | AUTOSEQUENCE profile | ||
AUTOSEQUENCE programmable | |||
AUTOSEQUENCE CE testing | |||
PASS/FAIL System Evaluation | |||
Custom Visual/Functional Inspection | |||
AUTOSEQUENCE Barcode testing | |||
Advanced User Interface | Colour display | ||
Touch screen | |||
Adaptable user interface | |||
Graphical Help Menus | |||
Database System Built In | |||
Programmable Memory Structure | |||
Multi-level Memory Organiser | |||
On-site Parameter Settings | |||
Automatic test sequence | Multitest sequence | ||
Main Features | Voltage | Voltage TRMS | |
Insulation Resistance | Test Voltage 50 V | ||
Test Voltage 100 V | |||
Test Voltage 250 V | |||
Test Voltage 500 V | |||
Test Voltage 1000 V | |||
Automatic Discharge | |||
DC Ramp Voltage Test/Varistor test | |||
Leakage Current | Differential Leakage | ||
Touch Leakage Current | |||
Substitute Leakage Current | |||
PE Leakage Current | |||
Discharge Time | 34 V (1…5 s) | ||
60 V (1…5 s) | |||
120 V (1…5 s) | |||
Functional | AC Current | ||
Load test | |||
Power Measurements | Active power | ||
Reactive power | |||
Apparent power | |||
Power factor | |||
Harmonics Analysis | THD current | ||
THD voltage | |||
HiPot Withstanding Test | Test Voltage 100…5000 VAC (500 VA) RAMP | ||
Test Voltage 100…5000 VAC (500 VA) BURN | |||
Test Voltage 1000 VAC (500 VA) | |||
Test Voltage 1890 VAC (500 VA) | |||
Test Voltage 2500 VAC (500 VA) | |||
Test Voltage 500…6000 VDC (500 VA) RAMP | |||
Test Voltage 100…2500 VAC (500 VA) RAMP | |||
Functional test | Leakages (Touc.,Diff.) &Power (P,S,Q,PF,…) | ||
Power P,Q,PF/Cos ΙΈ | |||
Apparent power - (S) | |||
Additional Features | Display | Back Light | |
PASS / FAIL Indicators | PASS / FAIL Indicators | ||
Buzzer | Buzzer | ||
Mains Supply / PE Check | Mains Supply / PE Check | ||
Keyboard | QWERTY Keyboard | ||
Connectivity | Black-Box Communication Protocol | ||
Communication Port USB | |||
Remotely controled | |||
Built-in Bluetooth | |||
Ethernet / Intranet Remote Communication | |||
Communication Port RS232 - PS/2 | |||
Memory | Downloadable | ||
Internal memory | |||
microSD memory card | |||
Uploadable | |||
Printing and scanning | QR-Code Printing / Scanning | ||
Simple-Code Printing | |||
Security | User Accounts | ||
Graphical user interface | Graphical on Line Help | ||
Special Accessories | Pasive 3-Phase Adapter | Pasive 3-Phase Adapter | |
Tip Commander | Tip Commander | ||
PC Software Package | MESM Compatible | ||
PC Software Package | |||
Professional reporting | |||
Connectivity accessories | Smart phones scanner | ||
Bluetooth Scanner | |||
Scanner | |||
Printer | |||
Bluetooth Printer | |||
RFID Reader | |||
NFC Reader | |||
NFC Reader-Writer | |||
Rack Mount | Rack Mount | ||
Standards Applied | IEC/EN 50191 | EN 50191 | |
IEC 60335 | IEC 60335-1 | ||
EN 60598 | EN 60598-1 | ||
IEC 60950 | IEC 60950 | ||
IEC 61439 | IEC 61439-1 | ||
IEC 61557 | IEC 61557 all relevant parts | ||
VDE 0701 - 0702 | VDE 0701 - 0702 |