MI 3155 EurotestXD is the newest flagship of Metrel’s most advanced line of multi-functional measuring instruments and is designed specifically for testing in industry. What differentiates this instrument from the rest is its ergonomic design and an intuitive user interface, encompassing a memory organizer and fully programmable AUTO SEQUENCEs, managed through a large colour touch screen display. It is fully compliant with functionality standards (e.g. IEC/EN 61557) and other reference standards for testing (e.g. IEC/EN/HD 60364-4-41,...) as is required for any instrument that performs TRMS current measurements, RCD tests, line and loop impedance tests with 3 (and 4) wires and earth resistance measurements. Besides those, the instrument supports a wide range of tests and measuring functions, including on-line voltage monitoring, phase sequence testing, varistor testing, PI/DAR calculation, luminance measurement, discharge time testing, ISFL measurements, IMD tests as well as functional and visual inspections.
![]() MI 3155 EurotestXD |
|---|
| Extra Features | Workspaces | El. LV Installation Safety Modes | |
| Industrial Mode | |||
| Medical Mode | |||
| EVSE Mode | |||
| Machine Mode | |||
| IT Vehicles / Mobile Units Mode | |||
| Lightning Mode | |||
| Project Structure | |||
| Visual Inspection Mode | |||
| Functional Inspection Mode | |||
| AUTOSEQUENCE ® | AUTOSEQUENCE profile | ||
| AUTOSEQUENCE programmable | |||
| AUTOSEQUENCE 3-Phase | |||
| AUTOSEQUENCE EVSE | |||
| PASS/FAIL System Evaluation | |||
| Custom Visual/Functional Inspection | |||
| AUTOSEQUENCE Barcode testing | |||
| Advanced User Interface | Colour display | ||
| Touch screen | |||
| Adaptable user interface | |||
| Graphical Help Menus | |||
| Database System Built In | |||
| Programmable Memory Structure | |||
| Multi-level Memory Organiser | |||
| On-site Parameter Settings | |||
| Auto Test | AUTO IT (U, Zln, Isc, Isfl, IMD) | ||
| AUTO TN (U, Zln, Zlpe, Rpe) | |||
| AUTO TN/RCD (U, Zln, Zs, Rpe) | |||
| AUTO TT (U, Zln, Zs, Uc) | |||
| Automatic test sequence | Multitest sequence | ||
| Main Features | Voltage | Frequency | |
| Voltage Monitoring | |||
| Voltage TRMS | |||
| Three Phase | 3-Phase system (Phase SEQUENCE) | ||
| Differential leakage current | |||
| Insulation Resistance | Autotest Insulation L-PE, N-PE, L-N | ||
| Test Voltage 50 V | |||
| Test Voltage 100 V | |||
| Test Voltage 250 V | |||
| Test Voltage 500 V | |||
| Test Voltage 1000 V | |||
| Test Voltage 2500 V | |||
| Test of IMD | |||
| Test of ELM | |||
| Test of RCM | |||
| Automatic Discharge | |||
| Max resistance range 999 MOhm | |||
| Calculation of PI | |||
| Calculation of DAR | |||
| DC Ramp Voltage Test/Varistor test | |||
| Leakage Current | Differential Leakage | ||
| Leakage Current (with optional Clamp) | |||
| ISFL: L1,L2 (First Fault Leakage) | |||
| AC Insulation Leakage | |||
| Z Line / Loop Impedance | Autotest TN/TT Z L-N, L-PE, dU, Uc | ||
| 16 Hz .. 400 Hz Extended range | |||
| DC circuit Zline/loop | |||
| Zline L-L, L-N Ipsc - 3 Wire | |||
| Zloop L-PE, Ipfc - 3 Wire | |||
| Zs (rcd) - 3 Wire | |||
| Zs (rcd) - 2 Wire | |||
| Zref, ΔU% | |||
| Fuse Tables | |||
| Test Current > 300A 4-wire | |||
| Max. Ipfc = 20kA | |||
| Zline L-L, L-N Ipsc - 4 wire | |||
| Zloop L-PE, Ipfc - 4 wire | |||
| Zline/loop mOhm high precision | |||
| RCD | RCD type AC | ||
| RCD type A | |||
| RCD type F | |||
| RCD type B | |||
| RCD type B+ | |||
| RCD Uc | |||
| RCD I Ramp | |||
| RCD Auto | |||
| RCD 3-Phase | |||
| EV-RCD | |||
| MI-RCD | |||
| RCD-S (Selective) | |||
| RCD (t) | |||
| PRCD | PRCD-S , PRCD-K | ||
| PRCD type AC | |||
| PRCD type A | |||
| PRCD type B | |||
| PRCD type B+ | |||
| PRCD type F | |||
| ELR industrial RCD | Earth (Electric) Leakage Relay | ||
| Earth / Ground Resistance | Earth Resistance 2-wire | ||
| Earth Resistance 3-wire | |||
| Two Iron Clamps Earth Resistance | |||
| S / P potential probe test | |||
| Wenner 4-wire Specific Earth Resistance | |||
| Discharge Time | 34 V (1…5 s) | ||
| 60 V (1…5 s) | |||
| 120 V (1…5 s) | |||
| Functional | Load test | ||
| Power Measurements | Active power | ||
| Reactive power | |||
| Apparent power | |||
| Power factor | |||
| Harmonics Analysis | THD current | ||
| THD voltage | |||
| Current harmonics | |||
| Voltage harmonics | |||
| Microclimatic Measurements | Illuminance | ||
| Current | Current TMS | ||
| Additional Features | Hand-Held | Hand-Held | |
| Display | LCD | ||
| Back Light | |||
| PASS / FAIL Indicators | PASS / FAIL Indicators | ||
| Buzzer | Buzzer | ||
| Mains Supply / PE Check | Mains Supply / PE Check | ||
| High precision resolution | High precision resolution | ||
| High precision resolution mOhm | |||
| Keyboard | QWERTY Keyboard | ||
| Connectivity | Communication Port USB | ||
| Built-in Bluetooth | |||
| Android Application | |||
| Communication Port RS232 - PS/2 | |||
| Memory | Downloadable | ||
| Internal memory | |||
| microSD memory card | |||
| Uploadable | |||
| Printing and scanning | QR-Code Printing / Scanning | ||
| Cable location | Cable location | ||
| Security | User Accounts | ||
| Power Supply | Battery Powered | ||
| Rechargeable Batteries in standard delivery | |||
| Graphical user interface | Graphical on Line Help | ||
| Special Accessories | Battery Charger | Battery Charger | |
| Active 3-Phase Adapter | Active 3-Phase Adapter | ||
| Pasive 3-Phase Adapter | Pasive 3-Phase Adapter | ||
| Active Euro Checkbox | Active Euro Checkbox | ||
| Active Ring Adapter EASYswitch | Active Ring Adapter EASYswitch (UK only) | ||
| Tip Commander | Tip Commander | ||
| Plug Commander | Plug Commander | ||
| PC Software Package | MESM Compatible | ||
| Report creation | |||
| PC Software Package | |||
| Professional reporting | |||
| Adapter for specific resistance ρ | ρ adapter | ||
| Cable Locator | Cable Locator | ||
| Current clamps | DC - Current Clamp | ||
| Generator Current Clamp | |||
| AC Leakage Current Clamp | |||
| Environment measurements | Lux Sensor | ||
| Connectivity accessories | Smart phones scanner | ||
| Test leads | Test lead with Kelvin probe or clamps | ||
| Standards Applied | IEC 60364 | IEC 60364-6 | |
| IEC 60364-7 | |||
| IEC 60364-4-41 | |||
| IEC 60755 | IEC 60755 | ||
| IEC 61008 | IEC 61008 | ||
| IEC 61009 | IEC 61009 | ||
| IEC 61557 | IEC 61557-1 | ||
| IEC 61557-2 | |||
| IEC 61557-3 | |||
| IEC 61557-4 | |||
| IEC 61557-5 | |||
| IEC 61557-6 | |||
| IEC 61557-7 | |||
| AS / NZ 3760 | AS / NZ 3760 | ||
| AS / NZ 3018 | AS / NZ 3018 | ||
| AS / NZ 3017 | AS / NZ 3017 | ||
| VDE 0413 | VDE 0413 | ||
| VDE 0100 | VDE 0100 | ||
| HD 384 | HD 384 | ||
| BS 7671 | BS 7671 17th Edition |