The top model of Metrel’s installation testers is MI 3105 EurotestXA. Features including “All-in-one” installation safety testing, AUTO SEQUENCE ® testing, integrated characteristics of fuses and RCDs (including B type), PASS / FAIL evaluation of test results, 10-level memory structure and built-in battery charger make the EurotestXA an exemplary instrument. Additional features include TRMS current measurement, 3-wire / one clamp / two clamps earth resistance and 4-wire specific earth resistance measurements, illumination measurement and fuse / fault locator function. All the results can be quickly saved and then downloaded via the EuroLink PRO software to the computer for evaluation and professional report generation after testing. The MI 3105 EurotestXA performs continuity, insulation, RCD, loop, line, voltage, frequency, earth resistance and phase sequence testing required by the EN 61557 standard.
MI 3105 EurotestXA |
---|
Extra Features | AUTOSEQUENCE ® | AUTOSEQUENCE profile | |
AUTOSEQUENCE programmable | |||
PASS/FAIL System Evaluation | |||
Custom Visual/Functional Inspection | |||
Advanced User Interface | Graphical Help Menus | ||
Programmable Memory Structure | |||
Multi-level Memory Organiser | |||
Auto Test | AUTO TN (U, Zln, Zlpe, Rpe) | ||
AUTO TN/RCD (U, Zln, Zs, Rpe) | |||
AUTO TT (U, Zln, Zs, Uc) | |||
Automatic test sequence | Multitest sequence | ||
Main Features | Voltage | Frequency | |
Voltage Monitoring | |||
Voltage TRMS | |||
Three Phase | 3-Phase system (Phase SEQUENCE) | ||
Differential leakage current | |||
Insulation Resistance | Autotest Insulation L-PE, N-PE, L-N | ||
Test Voltage 50 V | |||
Test Voltage 100 V | |||
Test Voltage 250 V | |||
Test Voltage 500 V | |||
Test Voltage 1000 V | |||
Test of IMD | |||
Automatic Discharge | |||
Leakage Current | Differential Leakage | ||
Leakage Current (with optional Clamp) | |||
ISFL: L1,L2 (First Fault Leakage) | |||
AC Insulation Leakage | |||
Z Line / Loop Impedance | 16 Hz .. 400 Hz Extended range | ||
Zline L-L, L-N Ipsc - 3 Wire | |||
Zloop L-PE, Ipfc - 3 Wire | |||
Zs (rcd) - 3 Wire | |||
Zref, ΔU% | |||
Fuse Tables | |||
Test Current > 300A 4-wire | |||
Max. Ipfc = 20kA | |||
Zline/loop mOhm high precision | |||
RCD | RCD type AC | ||
RCD type A | |||
RCD type F | |||
RCD type B | |||
RCD type B+ | |||
RCD Uc | |||
RCD I Ramp | |||
RCD Auto | |||
RCD 3-Phase | |||
RCD-S (Selective) | |||
RCD (t) | |||
Earth / Ground Resistance | Earth Resistance 2-wire | ||
Earth Resistance 3-wire | |||
Two Iron Clamps Earth Resistance | |||
Wenner 4-wire Specific Earth Resistance | |||
Additional Features | Hand-Held | Hand-Held | |
Display | LCD | ||
Back Light | |||
PASS / FAIL Indicators | PASS / FAIL Indicators | ||
Mains Supply / PE Check | Mains Supply / PE Check | ||
Keyboard | QWERTY Keyboard | ||
Connectivity | Communication Port USB | ||
Built-in Bluetooth | |||
Android Application | |||
Communication Port RS232 - PS/2 | |||
Memory | Downloadable | ||
Internal memory | |||
Uploadable | |||
Printing and scanning | QR-Code Printing / Scanning | ||
Power Supply | Battery Powered | ||
Rechargeable Batteries in standard delivery | |||
Graphical user interface | Graphical on Line Help | ||
Special Accessories | Battery Charger | Battery Charger | |
Pasive 3-Phase Adapter | Pasive 3-Phase Adapter | ||
Active Euro Checkbox | Active Euro Checkbox | ||
Active Ring Adapter EASYswitch | Active Ring Adapter EASYswitch (UK only) | ||
Tip Commander | Tip Commander | ||
Plug Commander | Plug Commander | ||
PC Software Package | Report creation | ||
PC Software Package | |||
Professional reporting | |||
Adapter for specific resistance ρ | ρ adapter | ||
Cable Locator | Cable Locator | ||
Current clamps | Generator Current Clamp | ||
AC Leakage Current Clamp | |||
Environment measurements | Lux Sensor | ||
Connectivity accessories | BT dongle | ||
Standards Applied | IEC 60364 | IEC 60364-6 | |
IEC 60364-7 | |||
IEC 60364-4-41 | |||
IEC 60755 | IEC 60755 | ||
IEC 61008 | IEC 61008 | ||
IEC 61009 | IEC 61009 | ||
IEC 61557 | IEC 61557-1 | ||
IEC 61557-2 | |||
IEC 61557-3 | |||
IEC 61557-4 | |||
IEC 61557-5 | |||
IEC 61557-6 | |||
IEC 61557-7 | |||
IEC 61557-10 | |||
AS / NZ 3760 | AS / NZ 3760 | ||
AS / NZ 3018 | AS / NZ 3018 | ||
AS / NZ 3017 | AS / NZ 3017 | ||
VDE 0413 | VDE 0413 | ||
VDE 0100 | VDE 0100 | ||
HD 384 | HD 384 | ||
BS 7671 | BS 7671 17th Edition |