EMI Solution - GSP-9330, GKT-008, GLN-5040A, GIT-5060

Features

  • Simplify the complicated EMC measurement and debugging
  • Including Conduction EMI Testing, Radiation EMI Testing
  • GSP-9330 Spectrum analyzer with EMI Mode
  • GKT-008 EMI Probe Set for pretest
  • GLN-5040A LISN for conduction testing
  • GIT-5060 AC isolated transformer
  • GPL-5010 Transient Limiter

  • Share on

Ordering Info :

Radiation EMI testing package

Conduction EMI testing package

Conduction and radiation EMI testing package

Radiation EMS testing package

 


 

implify the complicated EMC measurement and debugging!

 

The continuous integration and complication of consumer electronics have produced numerous electromagnetic radiation sources. EMC tests can ensure various electronics products’ safety and effectiveness.  In order to reduce the development cost and shorten development time, more and more companies are now focusing on EMC planning at the preliminary design phase. In addition to sending products to the lab, they are also looking for or try to establish an EMC solution which is cost effective and test effective diagnosis method. 

 

GW Instek introduces the latest and comprehensive EMC pre-compliance testing solution to meet customers’ requirements of EMC conduction and radiation testing during product development and verification stages. The EMC pre-compliance testing mode is ideal for electronics product development. With this solution, users can resolve problems at the earliest phase to avoid reconfiguration once the product development was finalized. Reducing product development cycles and verification laboratory fees are conducive to expediting the process of product verification and launch time.

 

For different test categories, GW Instek provides different test packages, 

Radiation EMI testing package

 

  • - Spectrum Analyzer: GSP-9330
  • - EMI Near Field Probe Set: GKT-008
  • - DC Block: ADB-008
  • - Transient Limiter: GPL-5010

 

Conduction and radiation EMI testing package

 

  • - Spectrum Analyzer: GSP-9330
  • - EMI Near Field Probe Set: GKT-008
  • - DC Block: ADB-008
  • - Two-Line V-Network(LISN): GLN-5040A
  • - Transient Limiter: GPL-5010
  • - Isolated Transformer: GIT-5060

 

Conduction EMI testing package

 

  • - Spectrum Analyzer: GSP-9330
  • - Two-Line V-Network(LISN): GLN-5040A
  • - Transient Limiter: GPL-5010
  • - Isolated Transformer: GIT-5060

 

Radiation EMS testing package
  • - Spectrum Analyzer: GSP-9330 + Tracking Generator
  • - EMI Near Field Probe Set: GKT-008

GSP-9330 specifications

Please check from GSP-9330 page.

 

GKT-008 specifications

PR-01

PR-02

Frequency Range

150 kHz to 30 MHz

Frequency Range

30MHz to 3GHz

Insertion Loss S21 / Frequency Response

5 dB / -3.6 dB (Avg.)

Insertion Loss S21 / Frequency Response

10 dB / -13.5 dB (Avg.)

Deviation of Insertion Loss

±1 dB

Deviation of Insertion Loss

±3 dB

Connector

50 Ω (SMA)

Connector

50 Ω (SMA)

Input Resistance

10 MΩ

Input Resistance

1 MΩ

Rated Voltage

300 VAC

Rated Voltage

50 VDC

ANT-04

ANT-05

Frequency Range

30 MHz to 3 GHz

Frequency Range

30MHz to 3GHz

Correction Factor / Frequency Response

10 dB / -26.5 dB (Avg.)

Correction Factor / Frequency Response

10 dB / -26.5 dB (Avg.)

Deviation of Correction Factor

±4 dB

Deviation of Correction Factor

±4 dB

Connector

50 Ω (SMA )

Connector

50 Ω (SMA)

Maximum Input Power

0.5 W

Maximum Input Power

0.5 W

 

 

GLN-5040A Two-Line V-Network specifications

Frequency Range

9kHz to 30MHz

Circuit Type

(50uH + 5Ω) // 50 Ω, V type

Test Circuit Phase Number

Single phase

AC Voltage Range

0 ~ 240V AC + 10%

AC Frequency Range

50 ~ 60 Hz ±5%

DC Voltage Range

0 ~ 50V DC

Maximum Permitted Current (Continuous) Country-Specific Connector Models Refer to Figure 1

Model 1

Model 2

Model 3

Model 4

Germany
(Schuko connector)

United Kingdom

China/Australia

USA/Japan

16A

13A

10A

15A

High Pass Filter (Alternative)  

150 kHz

Voltage Division Factor between EUT and Measuring Receiver Port

10 dB

Response Threshold of Built-In Pulse Limiter

130 dBuV

RF Output

BNC (F) / 50Ω

Artificial Hand Function

Embodied

EUT power supply Interface

German Standard Power Supply Socket

Operating Temperature

5 ∘C to 45∘ C

Storage Temperature

-40 ∘C to 70∘ C

Dimensions / Weight

338mm (L) x 237mm (W) x 133mm (H) / 4.2 Kg

Certification

EN61010-1:2010;  EN61326-1:2013;  EN61000-3-2:2014

EN61000-3-3:2013

 

GIT-5060 specifications

Capacity

900VA

Maximum Voltage

250V

Maximum Current

4A

Input Voltage Frequency

50~60Hz

Air Switch Current Limiting Threshold Value

5A

EUT Power Supply Connector

Universal Standard Power Socket

Operating Temperature

-15 ∘C  ~ 45∘ C

Storage Temperature

-40 ∘C ~ 70∘ C

Dimensions / Weight

338mm(L) x 237mm(W) x 133mm(H) / 11.5 Kg

Certification

EN61010-1:2010
EN61326-1:2013
EN61000-3-2:2014
EN61000-3-3:2013

 

GPL-5010規格specifications

Frequency Range

9kHz to 200MHz

Threshold Value Limit

50mW (17 dBm)

Input / Output Impedance

50Ω

Input Connector

BNC (F)

Output Connector

N-type (M)

Maximum Input Range

Continuous Power : 2.5W (34dBm)

Pulse Power : 10 kW (10us)

DC Voltage : ±12V

Insertion Loss

 

< 2 kHz

> 30 dB

9kHz to 50MHz

10dB±0.5dB

50MHz to 200MHz

9.5dB ~ 12.2dB

<6 kHz , >400MHz

> 13dB

Operating Temperature

0 ∘C to 55∘ C

Storage Temperature

-40 ∘C to 80∘C

Dimensions / Weight

18mm(L) x 44mm(W) x 23mm(H) / 92 g

Certification

EN61010-1:2010
EN61326-1:2013
EN61000-3-2:2014
EN61000-3-3:2013


Loading...