PFR-100 Series Fanless Multi-Range D.C. Power Supply

Features

  • Constant Power Output for 5 Times Multi-range(V&I) Operation
  • Natural Convection Cooling Design (Fanless Structure)
  • Preset Memory Function
  • Output ON/OFF Delay Function
  • CV, CC Priority Mode
  • Adjustable Slew Rate For Voltage and Current
  • Bleeder Circuit Control
  • Protections: OVP, OCP, AC FAIL and OTP
  • Support Front and Rear Panel Output
  • Built-in USB and RS-232/485 Interface Optional LAN+GPIB
  • Web Server Monitoring and Control
  • External Analog Control and Monitor Function
  • Remote Sensing Function

  • Share on

The PFR-100 series, a small and high-performance programmable D.C. power supply, adopts natural convection design to dissipate heat. The fanless structure allows users to focus on their experiments and tests in a quiet environment. Fanless power supply will not suck in dust and foreign objects, therefore, PFR-100 series has a longer life cycle compared with that of power supplies with fan.

 

Ordering Info :

PFR-100M
(0~250V/ 0~2A / 100W) Fanless Multi-Range DC Power Supply

PFR-100L
(0~50V/ 0~10A/ 100W) Fanless Multi-Range DC Power Supply


The PFR-100 series is a power supply with a five-fold rated power that allows users to self-define voltage and current under rated power conditions so as to satisfy them with wider voltage and current operational ranges. PFR-100 series, with rated 100W, provides two models: PFR-100L- maximum output voltage of 50V (at 2A) or maximum output current of 10A (at 10V); PFR-100M maximum output voltage of 250V (at 0.4A) or maximum output current of 2A (at 50V).


The PFR-100 series provides front and rear panel output terminals. The front panel output terminal helps users shorten test lead replacement time while conducting adjustment on front panel's function keys. The rear panel output terminal facilitates an easy wiring operation for rackmount assembly. 3U height, 70mm width and 2.5KG in weight have greatly elevated PFR-100 series portability. Furthermore, the multi-drop mode allows users to control up to 31 PFR-100 series without using switch/Hub that help users save the equipment cost.

  Model PFR-100L PFR-100M
OUTPUT RATING 

Rated Output Voltage
Rated Output Current
Rated Output Power

  50V
10A
100W

250V
2A
100W

REGULATION(CV)

Load Regulation (*2)
Line Regulation (*1)

  10mV
3mV 
 33mV
5mV
REGULATION(CC)

Load Regulation (*9)
Line Regulation (*1)

  10mA
8mA
3.2mA
1.2mA
RIPPLE & NOISE (*3)

Vp-p (*4)
Vr.m.s.(*5)
A r.m.s.

  50mV
4mV
10mA
 150mV
15mV
2mA
PROGRAMMING ACCURACY

Voltage
Current 

0.1% of setting +
0.2% of setting +

40mV
20mA
200mV
2mA
MEASUREMENT ACCURACY Voltage
Current
0.1% of reading +
0.2% of reading +
 40mV
20mA
 200mV
2mA
RESPONSE TIME 

Rise Time (*6)
Fall Time (*7)


Transient Response Time (*8) 

Rated load
Rated load
No load

50ms
100ms
500ms
1.5ms
200ms
300ms
3000ms
2ms
PROGRAMMING RESOLUTION Voltage
Current
   2mV
1mA
10mV
 0.1mA
MEASUREMENT RESOLUTION 

Voltage
Current

   2mV
1mA
10mV
 0.1mA 
PROTECTION FUNCTION 

Over Voltage Protection (OVP)
Over Current Protection (OCP)
Under Voltage Limit (UVL)
Over Temperature Protection (OTP)
Low AC Input Protection (AC-Fail)
Power Limit (Power Limit)

Setting range
Setting range
Setting range
Operation
Operation
Operation

 5~55V

1~11A
0~52.5V

Turn the output off.

Turn the output off.

Turn the output off.

5~275V
0.2~2.2A
0~262.5V

Turn the output off.

Turn the output off.

Turn the output off.

FRONT PANEL DISPLAY
ACCURACY, 4 DIGITS

Voltage
Current

0.1% of reading +
0.2% of reading +

40mV
20mA

200mV
2mA

ENVIRONMENT CONDITION

Operaing Temperature
Storage Temperature
Operating Humidity
Storage Humidity

 

0°C to 40°C
-20°C to 70°C
20% to 80% RH; No condensation
20% to 85% RH; No condensation 

READBACK TEMP. COEFFICIENT
(After A 30 Minute Warm-up)

Voltage
Current

 

100ppm/℃
200ppm/℃

OTHER  Analog Control
Interface
AC Input
  Yes
USB, RS-232/RS-485; Factory option: LAN/GPIB
85~265VAC, 47~63Hz, single pahse
DIMENSIONS & WEIGHT 70(W)x124(H)x300(D)mm; Approx.2.5kg

 

Notes:
*1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
*2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
*3: Measure with JEITA RC-9131B (1:1) probe
*4: Measurement frequency bandwidth is 10Hz to 20MHz.
*5: Measurement frequency bandwidth is 5Hz to 1MHz.
*6: From 10%~90% of rated output voltage, with rated resistive load.
*7: From 90%~10% of rated output voltage, with rated resistive load.
*8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a
load change from 50 to 100% of its rated output current.
*9: For load voltage change, equal to the unit voltage rating, constant input voltage.