Metrel MI 3325 MultiServicerXD is a top-of-the-line multifunctional instrument covering diverse industrial applications, where ruggedness and reliability are a must. In Metrel range of the instruments it is introduced as a successor of MI 3321 MultiServicerXA. The new platform integrated in the MI 3325 MultiServicerXD features support for colour touch screen technology, advanced memory organizer including large SD card storage media and state of the art AUTOSEQUENCE®s.
MI 3325 MultiServicerXD |
---|
Extra Features | Workspaces | Industrial Mode | |
Machine Mode | |||
Welding Mode | |||
Insulation Analysing Mode | |||
Portable appliance Mode | |||
Project Structure | |||
Visual Inspection Mode | |||
Functional Inspection Mode | |||
AUTOSEQUENCE ® | AUTOSEQUENCE profile | ||
AUTOSEQUENCE programmable | |||
AUTOSEQUENCE 3-Phase | |||
AUTOSEQUENCE Machine | |||
AUTOSEQUENCE Switchboard | |||
AUTOSEQUENCE PAT | |||
AUTOSEQUENCE Welding | |||
PASS/FAIL System Evaluation | |||
Custom Visual/Functional Inspection | |||
AUTOSEQUENCE Barcode testing | |||
AUTOSEQUENCE PRCD | |||
Advanced User Interface | Colour display | ||
Touch screen | |||
Adaptable user interface | |||
Graphical Help Menus | |||
Database System Built In | |||
Programmable Memory Structure | |||
Multi-level Memory Organiser | |||
On-site Parameter Settings | |||
Automatic test sequence | Multitest sequence | ||
Main Features | Three Phase | 3-Phase system (Phase SEQUENCE) | |
3-Phase power readout | |||
Differential leakage current | |||
Power / Functional test | |||
Active power readout | |||
Reactive power readout | |||
Power factor readout | |||
3-Phase RCD / Test current | |||
Portable RCD trip-out (B type PRCD) | |||
Welding circuit leakage current | |||
Primary leakage current readout | |||
No load voltage readout | |||
Functional | Leakages (Touc.,Di.) &Power (P,S,Q,PF,…) | ||
Apparent power - (S) | |||
Harmonics | |||
AC Current | |||
Load test | |||
Power P, Q, PF/Cosφ | |||
Power Measurements | Active power | ||
Reactive power | |||
Apparent power | |||
Power factor | |||
Earth Bond / Continuity | Max Test Current 10 A 4-wire | ||
Max Test Current 25 A 2-wire | |||
Max Test Current 200 mA 2-wire | |||
Max Test Current 200 mA 4-wire | |||
Max Test Current 10 A 2-wire (Voltage drop) | |||
Max Test Current 4 A 4-wire | |||
Max Test Current 10 A 2-wire | |||
Max Test current 25 A 4-wire | |||
Max Test Current 4 A 2-wire | |||
Insulation Resistance | Test Voltage 50 V | ||
Test Voltage 100 V | |||
Test Voltage 250 V | |||
Test Voltage 500 V | |||
Test Voltage 1000 V | |||
Max resistance range 999 MOhm | |||
Leakage Current | Differential Leakage | ||
Touch Leakage Current | |||
Substitute Leakage Current | |||
PE Leakage Current | |||
Leakage Current (with optional Clamp) | |||
AC Insulation Leakage | |||
HiPot Withstanding Test | Test Voltage 5000 VAC (250 VA) | ||
Test Voltage Programmable | |||
Z Line / Loop Impedance | Zline L-L, L-N Ipsc - 3 Wire | ||
Zloop L-PE, Ipfc - 3 Wire | |||
Zloop L-PE, Ipfc - 2 Wire | |||
Zs (rcd) - 3 Wire | |||
Zref, ΔU% | |||
Fuse Tables | |||
RCD | RCD type AC | ||
RCD type A | |||
RCD type B | |||
RCD type B+ | |||
RCD Uc | |||
RCD I Ramp | |||
RCD (t) | |||
PRCD | PRCD-S , PRCD-K | ||
PRCD type AC | |||
PRCD type A | |||
PRCD type B | |||
PRCD type B+ | |||
PRCD type F | |||
Polarity | IEC lead test / polarity | ||
3-Phase Active polarity (with P-RCD) | |||
1-Phase Active polarity (with P-RCD) | |||
Discharge Time | 34 V (1…5 s) | ||
60 V (1…5 s) | |||
120 V (1…5 s) | |||
Harmonics Analysis | THD current | ||
THD voltage | |||
Voltage DC | Voltage DC | ||
Voltage AC | Frequency | ||
Voltage TRMS | |||
Current DC | Current DC | ||
Current AC | Current TRMS | ||
Additional Features | Security | User Accounts | |
Memory | Downloadable | ||
Internal memory | |||
microSD memory card | |||
Uploadable | |||
Voltage Monitoring | Voltage Monitoring | ||
Remote communication | Remotely controled | ||
Ethernet / Intranet Remote Communication | |||
Communication Port | Communication Port USB | ||
Communication Port RS232 - PS/2 | |||
Built-in Bluetooth | Built-in Bluetooth | ||
Mobile Application | Android Application | ||
Printing / Scanning | Barcode Printing / Scanning | ||
QR-Code Printing / Scanning | |||
Simple-Code Printing | |||
Special Accessories | Active 3-Phase Adapter | Active 3-Phase Adapter | |
Pasive 3-Phase Adapter | Pasive 3-Phase Adapter | ||
PC Software Package | MESM Compatible | ||
Report creation | |||
PC Software Package | |||
Professional reporting | |||
Rack Mount | Rack Mount | ||
Current clamps | AC Leakage Current Clamp | ||
Bluetooth Scanner | Bluetooth Scanner | ||
Scanner | Scanner | ||
Printer | Printer | ||
Bluetooth Printer | Bluetooth Printer | ||
RFID | RFID Reader | ||
NFC | NFC Reader | ||
NFC Reader | |||
Standards Applied | AS / NZ 3760 | AS / NZ 3760 | |
AS / NZ 3017 | AS / NZ 3017 | ||
VDE 0701 - 0702 | VDE 0701 - 0702 | ||
BS 7671 | BS 7671 17th Edition | ||
IEC/EN 60204 | IEC/EN 60204-1 | ||
IEC/EN 60364 | IEC/EN 60364 series | ||
IEC/EN 60364-4-41 | |||
IEC/EN 60974 | IEC/EN 60974 series | ||
IEC/EN 60974-4 / VDE 0544-4 | |||
IEC/EN 61008 | IEC/EN 61008 | ||
IEC/EN 61009 | IEC/EN 61009 | ||
IEC/EN 61439 | IEC/EN 61439-1 |