MI 3100 SE EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 SE EurotestEASI enables on-line voltage monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results. All the results can be quickly saved and referenced on the instrument and then downloaded via the EuroLink PRO software (included in the standard set) to the computer for evaluation and report generation after testing.
MI 3100 SE EurotestEASI |
---|
Extra Features | AUTOSEQUENCE | PASS/FAIL System Evaluation | |
Advanced User Interface | Graphical Help Menus | ||
Auto Test | |||
AUTO TN (U, Zln, Zlpe, Rpe) | |||
AUTO TN/RCD (U, Zln, Zs, Rpe) | |||
AUTO TT (U, Zln, Zs, Uc) | |||
Automatic Sequence | Multitest sequence | ||
Main Features | Voltage | Frequency | |
Voltage Monitoring | |||
Voltage TRMS | |||
Three Phase | 3-Phase system (Phase SEQUENCE) | ||
Insulation Resistance | Test Voltage 50 V | ||
Test Voltage 100 V | |||
Test Voltage 250 V | |||
Test Voltage 500 V | |||
Test Voltage 1000 V | |||
Automatic Discharge | |||
Leakage Current | Differential Leakage | ||
Leakage Current (with optional Clamp) | |||
ISFL: L1,L2 (First Fault Leakage) | |||
AC Insulation Leakage | |||
Z Line / Loop Impedance | Zline L-L, L-N Ipsc - 3 Wire | ||
Zloop L-PE, Ipfc - 3 Wire | |||
Zs (rcd) - 3 Wire | |||
Zref, ΔU% | |||
Fuse Tables | |||
RCD | RCD type AC | ||
RCD type A | |||
RCD type F | |||
RCD Uc | |||
RCD I Ramp | |||
RCD Auto | |||
RCD 3-Phase | |||
RCD-S (Selective) | |||
RCD (t) | |||
PRCD | PRCD-S , PRCD-K | ||
PRCD type AC | |||
PRCD type A | |||
PRCD type B | |||
PRCD type B+ | |||
PRCD type F | |||
Earth / Ground Resistance | Earth Resistance 2-wire | ||
Earth Resistance 3-wire | |||
Additional Features | Hand-Held | Hand-Held | |
Display | LCD | ||
Backlight | |||
PASS / FAIL Indicators | PASS / FAIL Indicators | ||
Mains Supply / PE Check | Mains Supply / PE Check | ||
Communication Port USB | |||
Built-in Bluetooth | |||
Android Application | |||
Communication Port RS232 - PS/2 | |||
Memory | Downloadable | ||
Internal memory | |||
Uploadable | |||
Printing and scanning | QR-Code Printing / Scanning | ||
Power Supply | Battery Powered | ||
Rechargeable Batteries in standard delivery | |||
Graphical user interface | Graphical on Line Help | ||
Special Accessories | Battery Charger | Battery Charger | |
Pasive 3-Phase Adapter | Pasive 3-Phase Adapter | ||
Active Euro Checkbox | Active Euro Checkbox | ||
Active Ring Adapter EASYswitch | Active Ring Adapter EASYswitch (UK Only) | ||
Tip Commander | Tip Commander | ||
Plug Commander | Plug Commander | ||
PC Software Package | MESM Compatible | ||
Report creation | |||
PC Software Package | |||
Professional reporting | |||
Connectivity accessories | BT dongle | ||
Standards Applied | IEC 60364 | IEC 60364-6 | |
IEC 60364-4-41 | |||
IEC 60755 | IEC 60755 | ||
IEC 61008 | IEC 61008 | ||
IEC 61009 | IEC 61009 | ||
IEC 61557 | IEC 61557-1 | ||
IEC 61557-2 | |||
IEC 61557-3 | |||
IEC 61557-4 | |||
IEC 61557-5 | |||
IEC 61557-6 | |||
IEC 61557-7 | |||
IEC 61557-10 | |||
IEC 61557-12 | |||
AS / NZ 3760 | AS / NZ 3760 | ||
AS / NZ 3018 | AS / NZ 3018 | ||
AS / NZ 3017 | AS / NZ 3017 | ||
VDE 0413 | VDE 0413 | ||
VDE 0100 | VDE 0100 | ||
HD 384 | HD 384 | ||
BS 7671 | BS 7671 17th Edition |