Key features

 

  • Programmable AUTO SEQUENCEs. *
  • Predefined profile dependent
  • AUTO SEQUENCEs.
  • Predefined Automatic tests: 
        Auto TT (U, Zln, Zs, Uc); 
        Auto TN/RCD (U, Zln, Zs, Rpe); 
        Auto TN (U, Zln, Zlpe, Rpe); 
        Auto IT (U, Zln, Isc, Isfl, IMD).
  • Functional inspections.
  • Visual inspections.
  • Custom inspections (visual and functional) which may be incorporated into AUTO SEQUENCEs.
  • EVSE AUTO SEQUENCEs and function inspections.
  • Machine functional and visual inspections.
  • Built-in help screens for referencing on site.
  • Built-in fuse tables for automatic evaluation of the line / loop impedance result.
  • Monitoring of all 3 voltages in real-time.
  • Automatic polarity reversal on continuity test.
  • Automated RCD testing procedure (RCD AUTO).
  • Automated Impedance testing procedure (Z AUTO).
  • Measurement filtering according  to the selected area group.
  • Built-in charger and rechargeable batteries as standard accessory.
  • BT communication with PC, Android tablets and smart phones via built-in BT.
  • PC SW Metrel ES Manager (structure and report creation, data upload/download). *
  • Optional aMESM Android APP (structure and report creation, data upload/download). *

Technical data

  • Dimensions (w x h x l): 252 x 111 x 165 mm.
  • Mass (without accessories): 1.78 kg.

Category: Multifunction tester

Tags: MI 3155, MI3155, EurotestXD, alat tester, metrel, metrel indonesia

MI 3155 EurotestXD is the newest flagship of Metrel’s most advanced line of multi-functional measuring instruments and is designed specifically for testing in industry. What differentiates this instrument from the rest is its ergonomic design and an intuitive user interface, encompassing a memory organizer and fully programmable AUTO SEQUENCEs, managed through a large colour touch screen display. It is fully compliant with functionality standards (e.g. IEC/EN 61557) and other reference standards for testing (e.g. IEC/EN/HD 60364-4-41,...) as is required for any instrument that performs TRMS current measurements, RCD tests, line and loop impedance tests with 3 (and 4) wires and earth resistance measurements. Besides those, the instrument supports a wide range of tests and measuring functions, including on-line voltage monitoring, phase sequence testing, varistor testing, PI/DAR calculation, luminance measurement, discharge time testing, ISFL measurements, IMD tests as well as functional and visual inspections.

ket Function is supported
ket Function is not supported
ket Function is optional

 


MI 3155 EurotestXD

 

 

 

 

 

Extra Features Workspaces El. LV Installation Safety Modes
Industrial Mode
Medical Mode
EVSE Mode
Machine Mode
IT Vehicles / Mobile Units Mode
Lightning Mode
Project Structure
Visual Inspection Mode
Functional Inspection Mode
AUTOSEQUENCE ® AUTOSEQUENCE profile
AUTOSEQUENCE programmable
AUTOSEQUENCE 3-Phase
AUTOSEQUENCE EVSE
PASS/FAIL System Evaluation
Custom Visual/Functional Inspection
AUTOSEQUENCE Barcode testing
Advanced User Interface Colour display
Touch screen
Adaptable user interface
Graphical Help Menus
Database System Built In
Programmable Memory Structure
Multi-level Memory Organiser
On-site Parameter Settings
Auto Test AUTO IT (U, Zln, Isc, Isfl, IMD)
AUTO TN (U, Zln, Zlpe, Rpe)
AUTO TN/RCD (U, Zln, Zs, Rpe)
AUTO TT (U, Zln, Zs, Uc)
Automatic test sequence Multitest sequence
Main Features Voltage Frequency
Voltage Monitoring
Voltage TRMS
Three Phase 3-Phase system (Phase SEQUENCE)
DiffŒerential leakage current
Insulation Resistance Autotest Insulation L-PE, N-PE, L-N
Test Voltage 50 V
Test Voltage 100 V
Test Voltage 250 V
Test Voltage 500 V
Test Voltage 1000 V
Test Voltage 2500 V
Test of IMD
Test of ELM
Test of RCM
Automatic Discharge
Max resistance range 999 MOhm
Calculation of PI
Calculation of DAR
DC Ramp Voltage Test/Varistor test
Leakage Current DiffŒerential Leakage
Leakage Current (with optional Clamp)
ISFL: L1,L2 (First Fault Leakage)
AC Insulation Leakage
Z Line / Loop Impedance Autotest TN/TT Z L-N, L-PE, dU, Uc
16 Hz .. 400 Hz Extended range
DC circuit Zline/loop
Zline L-L, L-N Ipsc - 3 Wire
Zloop L-PE, Ipfc - 3 Wire
Zs (rcd) - 3 Wire
Zs (rcd) - 2 Wire
Zref, ΔU%
Fuse Tables
Test Current > 300A 4-wire
Max. Ipfc = 20kA
Zline L-L, L-N Ipsc - 4 wire
Zloop L-PE, Ipfc - 4 wire
Zline/loop mOhm high precision
RCD RCD type AC
RCD type A
RCD type F
RCD type B
RCD type B+
RCD Uc
RCD I Ramp
RCD Auto
RCD 3-Phase
EV-RCD
MI-RCD
RCD-S (Selective)
RCD (t)
PRCD PRCD-S , PRCD-K
PRCD type AC
PRCD type A
PRCD type B
PRCD type B+
PRCD type F
ELR industrial RCD Earth (Electric) Leakage Relay
Earth / Ground Resistance Earth Resistance 2-wire
Earth Resistance 3-wire
Two Iron Clamps Earth Resistance
S / P potential probe test
Wenner 4-wire Specific Earth Resistance
Discharge Time 34 V (1…5 s)
60 V (1…5 s)
120 V (1…5 s)
Functional Load test
Power Measurements Active power
Reactive power
Apparent power
Power factor
Harmonics Analysis THD current
THD voltage
Current harmonics
Voltage harmonics
Microclimatic Measurements Illuminance
Current Current TMS
Additional Features Hand-Held Hand-Held
Display LCD
Back Light
PASS / FAIL Indicators PASS / FAIL Indicators
Buzzer Buzzer
Mains Supply / PE Check Mains Supply / PE Check
High precision resolution High precision resolution
High precision resolution mOhm
Keyboard QWERTY Keyboard
Connectivity Communication Port USB
Built-in Bluetooth
Android Application
Communication Port RS232 - PS/2
Memory Downloadable
Internal memory
microSD memory card
Uploadable
Printing and scanning QR-Code Printing / Scanning
Cable location Cable location
Security User Accounts
Power Supply Battery Powered
Rechargeable Batteries in standard delivery
Graphical user interface Graphical on Line Help
Special Accessories Battery Charger Battery Charger
Active 3-Phase Adapter Active 3-Phase Adapter
Pasive 3-Phase Adapter Pasive 3-Phase Adapter
Active Euro Checkbox Active Euro Checkbox
Active Ring Adapter EASYswitch Active Ring Adapter EASYswitch (UK only)
Tip Commander Tip Commander
Plug Commander Plug Commander
PC Software Package MESM Compatible
Report creation
PC Software Package
Professional reporting
Adapter for specific resistance ρ ρ adapter
Cable Locator Cable Locator
Current clamps DC - Current Clamp
Generator Current Clamp
AC Leakage Current Clamp
Environment measurements Lux Sensor
Connectivity accessories Smart phones scanner
Test leads Test lead with Kelvin probe or clamps
Standards Applied IEC 60364 IEC 60364-6
IEC 60364-7
IEC 60364-4-41
IEC 60755 IEC 60755
IEC 61008 IEC 61008
IEC 61009 IEC 61009
IEC 61557 IEC 61557-1
IEC 61557-2
IEC 61557-3
IEC 61557-4
IEC 61557-5
IEC 61557-6
IEC 61557-7
AS / NZ 3760 AS / NZ 3760
AS / NZ 3018 AS / NZ 3018
AS / NZ 3017 AS / NZ 3017
VDE 0413 VDE 0413
VDE 0100 VDE 0100
HD 384 HD 384
BS 7671 BS 7671 17th Edition